60 Hz AC LINE FILTER - #26 MATERIAL (single layer winding)

AC Amps 1 2 4 6 10 15 20 30
Wire awg * 28 24 21 19 15 13 11 9
Part No. Induct (uH) / Turns
T-37-26 130 uH/41 turns 50 uH/27 turns 15 uH/15 turns 6.7 uH/10 turns 2.4 uH/6 turns 1.1 uH/4 turns 0.6 uH/3 turns .07 uH/1 turns
T-50-26 460 uH/63 turns 150 uH/37 turns 59 uH/25 turns 26 uH/17 turns 9.5 uH/10 turns 4.2 uH/7 turns 2.4 uH/5 turns 1.0 uH/3 turns
T-80-26 1.6 mH/108 turns 550 uH/66 turns 213 uH/45 turns 94 uH/30 turns 34 uH/18 turns 15 uH/12 turns 8.5 uH/9 turns 3.8 uH/6 turns
T-94-26 2.9 mH/123 turns 950 uH/75 turns 375 uH/52 turns 156 uH/33 turns 56 uH/20 turns 25 uH/13 turns 14 uH/10 turns 6.2 uH/7 turns
T-130-26 7.2 mH/173 turns 2.5 mH/107 turns 1 mH/75 turns 444 uH/50 turns 160 uH/30 turns 71 uH/20 turns 40 uH/15 turns 18 uH/10 turns
T-157-26 13.6 mH/213 turns 4.6 mH/139 turns 1.8 mH/93 turns 800 uH/62 turns 290 uH/37 turns 129 uH/25 turns 73 uH/18 turns 32 uH/12 turns
* wire size based on max temp. rise 40' C
wire metric conversion table

01/06/03